FT-NIR QuasIR 4000

Optical System: Wavelength Range 12,800 - 4,000 cm-1 Signal-to-Noise Ratio > 20,000:1 Noise Better than 20 micro au Detector TE cooled InGaAs Laser Life > 10 years NIR Source Life > 20,000 hours, user replaceable Desiccant User Replaceable Resolution: 4 cm^-1 Wave number reproducibility : < 0.1 cm-1 @ 7181.68 cm-1 Wave number Accurancy: < 0.1 cm-1 @ 7181.68 cm-1 Photometric Accurncy: Better than 0.1%T Sampling area 23mm Interforemeter: PermAlign™ Permanently aligned, high stability, insentive to vibration, insentive to temperature change and insentive to dust. Construction: Sealed optic huosing, desiccated IR Source: High energy air cooled NIR source, easy to replace long life diode Laser Beamsplitter: Quartz substrate with proprietary coating Validation: Internal Validation Unit Spectrometer Calibration: water vapour for OQ/PQ Computer interface: USB connection Spectroscopy software: SpectralSage™ easy to use. Fully GMP Upgrade to QuasIR 4000, with temperature control Dimensions 44.5 x 24.1 x 14.5 cm Weight < 9.6 kg Sampling Mode Diffuse Reflectance for solids; Transmission for liquids Sampling Devices 1) High performance gold-coated integrating sphere 2) Transmission cell with optional temperature control Automated Verification & Automatic, internal, 4-position validation wheel Instrument Diagnostics Power Supply 12V / 3A Supply, 60W max Communication USB Operating Temperature 0 - 40°C Enclosure Protection IP54 (dust) Regulatory Compliance EMC directive 2004/108/EC RoHS directive 2002/95/EC WEEE directive 2002/96/EC SOLID APPLICATION INTEGRATING SPHERE for Solid Application Reflectance & Transreflectance Methode Range: 12,800 -4,000 cm^-1 Detector: TE cooled InGaAs detector Integratingsphere With Gold Coated: Better for heterogenous and unground samples QuasIR™ 4000 has an enhanced 23mm sampling area, which is up to 5 times larger than competitive products MS-3020-1 Petri dish adapter for sample spinner MS-3000-1 (requires PN PN MS-3000-1) MS-3010-1 Standard 100 mm sampling cup for sample spinner MS-3000-1 (requires PN MS-3000-1) LIQUID APPLICATION SAMPLE COMPARTMENT for Liquid Application Transmission Methode Internal Heather: Up to 100˚C, cool to 20˚C Temperature control option for QuasIR 4000 transmission compartment Suitble for AOCS Method of lodine value messurement at 75˚C with transmission detector InGAs Hetable vial holder for transmission measurement for use inside the sample compartment with the QuansIR 4000 spectrometer. This Accessory allows the temperature controlled transmission measurement of samples in vials with a diameter up to 10 mm, Temperature range: 20 to 100˚C. The temperature is selected trough the application software. MS-4020-1 Consumables: 8mm vials, package of 200, with caps Glass Vials, 8mm diameter, wall thickness 0.8mm Includes stopper (1 box @ 100pcs) SOFTWARE 21 CFR 11 compliant electronic signature capability Spectral Sage Software, single license Spectral Sage QuasIR Data Collection Package, single license Spectral Sage QuasIR Data Collection Package, single license Dongle locked license, installed and internally cabled to instrument Spectral Sage EZ user interface